激情综合啪啪6月丁香,久久久久国产精品91福利,99精品日韩欧美在线观看,91成人午夜福利在线观看国产

行業(yè)產(chǎn)品

  • 行業(yè)產(chǎn)品

廈門慧嘉生物科技有限公司


當(dāng)前位置:廈門慧嘉生物科技有限公司>資料下載>CSB-E08037r大鼠*釋放激素(GnRH)ELISA試劑盒說明書
資料下載

CSB-E08037r大鼠*釋放激素(GnRH)ELISA試劑盒說明書

閱讀:527發(fā)布時(shí)間:2012-02-10

  • 提供商

    廈門慧嘉生物科技有限公司

  • 資料大小

    120.8KB

  • 資料圖片

  • 下載次數(shù)

    132次

  • 資料類型

    WORD 文檔

  • 瀏覽次數(shù)

    527次

  • 免費(fèi)下載

    點(diǎn)擊下載


 

 Rat gonadotropin-releasing hormone(GnRH)ELISA Kit
Catalog No. CSB-E08037r
(96T)
This immunoassay kit allows for the in vitro quantitative determination of rat GnRH concentrations in serum, plasma.
Expiration date six months from the date of manufacture
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
 
廈門慧嘉生物長(zhǎng)期經(jīng)營(yíng)ELISA試劑盒及Santa/Abcam抗體、Prospec細(xì)胞因子、Sigma/Amresco/Qiagen、Axygen耗材等生物試劑產(chǎn)品。誠信經(jīng)營(yíng),價(jià)格實(shí)惠,服務(wù)周到,質(zhì)量有保證。歡迎廣告老師來詢!:  :  1048735792 或登陸/download(向客服人員索取原版說明書)
 
PRINCIPLE OF THE ASSAY
The microtiter plate provided in this kit has been pre-coated with a goat-anti-rabbit antibody. Sta-n-dards or samples are then added to the appropriate microtiter plate wells with a HRP-conjugated GnRH a-n-d antibody preparation specific for GnRH a-n-d incubated. Then substrate solutions are added to each well. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution a-n-d the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of GnRH in the samples is then determined by comparing the O.D. of the samples to the sta-n-dard curve.
DETECTION RANGE
3.2 pg/ml-800 pg/ml. The sta-n-dard curve concentrations used for the ELISA’s were 800 pg/ml, 240 pg/ml, 40 pg/ml, 8 pg/ml, 3.2 pg/ml.
SPECIFICITY
This assay recognizes rat GnRH. No significant cross-reactivity or interference was observed.
SENSITIVITY
The minimum detectable dose of rat GnRH is typically less than
3.2 pg/ml. The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero.
MATERIALS PROVIDED STORAGE

Reagent
 
 
 
Quantity
Assay plate
 
 
 
1
Standards (S0-S5)
 
 
 
6 x 0.5 ml
HRP-conjugate
 
 
 
1 x 6 ml
Antibody
 
 
 
1 x 6 ml
Wash Buffer
 
 
 
1 x 15 ml (20×concentrate)
Substrate A
 
 
 
1 x 7 ml
Substrate B
 
 
 
1 x 7 ml
Stop Solution
 
 
 
1 x 7 ml
Standard
S0
S1
S 2
S3
S4
S5
Concentration (pg/ml)
0
3.2
8
40
240
800

 
1.    Unopened test kits should be stored at 2-8?C upon receipt a-n-d the microtiter plate should be kept in a sealed bag. The test kit may be used throughout the expiration date of the kit, provided it is stored as prescribed above. Refer to the package label for the expiration date.
2.    Opened test plate should be stored at 2-8?C in the aluminum foil bag with desiccants to minimize exposure to damp air. The kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
3.    A microtiter plate reader with a ba-n-dwidth of 10 nm or less a-n-d an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement.
 
REAGENT PREPARATION
1         Bring all reagents a-n-d plate to room temperature for at least 30 minutes before use. Unused wells need store at 2-8a-n-d avoid sunlight.
2         Wash Buffer If crystals have formed in the concentrate, warm to room temperature a-n-d mix gently until the crystals have compley dissolved. Dilute 15 ml of Wash Buffer Concentrate into deionized or distilled water to prepare 300 ml of Wash Buffer.
 
Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye, ha-n-d, face, a-n-d clothing protection when using this material.
OTHER SUPPLIES REQUIRED
1          Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
2          Pipettes a-n-d pipette tips.
3          Deionized or distilled water.
4          Squirt bottle, manifold dispenser, or automated microplate washer.
5          An incubator which can provide stable incubation conditions up to 37°C±0.5°C.
 
SAMPLE COLLECTION A-N-D STORAGE
? Serum Use a serum separator tube (SST) a-n-d allow
samples to clot for 30 minutes before centrifugation for 15 minutes at 1000 g. Remove serum a-n-d assay immediay or aliquot a-n-d store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
? Plasma Collect plasma using citrate, EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 g within 30 minutes of collection. Assay immediay or aliquot a-n-d store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
Note: Grossly hemolyzed samples are not suitable for use in this assay.
ASSAY PROCEDURE
Bring all reagents a-n-d samples to room temperature before use. It is recommended that all samples, sta-n-dards, a-n-d controls be assayed in duplicate. All the reagents should be added directly to the liquid level in the well. The pipette should avoid contacting the inner wall of the well.
1         Set a Blank well without any solution. Add 50μl of Sta-n-dard or Sample per well. Sta-n-dard need test in duplicate.
2         Add 50μl of HRP-conjugate to each well (not to Blank well), then 50μl Antibody to each well. Mix well a-n-d then incubate for 1 hour at 37°C.
3         Fill each well with Wash Buffer (about 200μl), stay for 10 seconds a-n-d Spinning. Repeat the process for a total of three washes. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate a-n-d blot it against clean paper towels.
4         Add 50μl of Substrate A a-n-d 50μl Substrate B to each well, mix well. Incubate for 15 minutes at 37°C. Keeping the plate away from drafts a-n-d other temperature fluctuations in the dark.
5         Add 50μl of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
6         Determine the optical density of each well within 10 minutes, using a microplate reader set to 450 nm.
 
CALCULATION OF RESULTS
Using the professional soft "Curve Exert 1.3" to make a sta-n-dard curve is recommended, which can be downloaded from our web.
Average the duplicate readings for each sta-n-dard, Blank, a-n-d sample a-n-d subtract the optical density of Blank. Create a sta-n-dard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a sta-n-dard curve by plotting the mean absorbance for each sta-n-dard on the x-axis against the concentration on the y-axis a-n-d draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the GnRH concentrations versus the log of the O.D. a-n-d the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the sta-n-dard curve must be multiplied by the dilution factor.
LIMITATIONS OF THE PROCEDURE
1          The kit should not be used beyond the expiration date on the kit label.
2          Do not mix or substitute reagents with those from other lots or sources.
3          If samples generate values higher than the highest sta-n-dard, dilute the samples with the appropriate Diluent a-n-d repeat the assay.
4          Any variation in operator, pipetting technique, washing technique, incubation time or temperature, a-n-d kit age can cause variation in binding.
5          This assay is designed to eliminate interference by soluble receptors, binding proteins, a-n-d other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
 
TECHNICAL HINTS
1          Centrifuge vials before opening to collect contents.
2          To avoid cross-contamination, change pipette tips between additions of each sta-n-dard level, between sample additions, a-n-d between reagent additions. Also, use separate reservoirs for each reagent.
3          When using an automated plate washer, adding a 30 second soak period following the addition of wash buffer, a-n-d/or rotating the plate 180 degrees between wash steps may improve assay precision.
4          To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary. Sealers can not be reused.
5          Substrate Solution should remain colorless or light blue until added to the plate. Keep Substrate Solution protected from light. Substrate Solution should change from colorless or light blue to gradations of blue.
6          Stop Solution should be added to the plate in the same order as the Substrate Solution. The color developed in the wells will turn from blue to yellow upon addition of the Stop Solution. Wells that are green in color indicate that the Stop Solution has not mixed thoroughly with the Substrate Solution.

環(huán)保在線 設(shè)計(jì)制作,未經(jīng)允許翻錄必究 .? ? ? Copyright(C)?2025 http://www.hg1112.cn,All rights reserved.

以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),環(huán)保在線對(duì)此不承擔(dān)任何保證責(zé)任。 溫馨提示:為規(guī)避購買風(fēng)險(xiǎn),建議您在購買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。
15168338725

會(huì)員登錄

×

請(qǐng)輸入賬號(hào)

請(qǐng)輸入密碼

=

請(qǐng)輸驗(yàn)證碼

收藏該商鋪

請(qǐng) 登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
在线免费看污视频| 日日爱黄色毛片视频| 操纯欲女生小穴视频| 无码爆一二三区免费视频| 美女骚逼被操出白浆| 最新日本一区二区三区免费看| 国产精品三级一区二区| 国产剧情使劲操我逼| 裸毛片视频在线视频| 人妻含泪让粗大挺进| 一级风流国产片a级| 操你的骚逼粉嫩AV| 大鸡巴干浪穴视频| 91精品国产综合久久久蜜| 日韩一区二区三区国色天香| 老湿机69福免费破解版| 日本中文字幕无人区一区二区| 99精品欧美一区二区三区喷胶| 九热中文字幕在线| 操我骚逼抽插视频| 美女人的逼免费观看| 日韩av午夜福利在线观看| 欧美成人精品一区二区免费看| 中国熟女色av夜夜嗨| 国产一区二区三区午夜精品久久| 日韩 中文字幕在线最新| 美女主播被操流水| 男人天堂av在线免费看| 无码社区在线观看| 男女操逼视频嫩嫩| 精品一区二区久久久久无码| 国产女做a爱全免费视频| 美女穿黑丝被大鸡巴猛操| 欧美精品国产一区二区在线观看| 欧美大鸡巴操穴日韩| 亚洲av无一区二区三区综合| 欧亚洲嫩模精品一区三区| 女人被大鸡吧操逼| 校花内射国产麻豆欧美一区| 亚洲AV无码一区二区三区天堂古| 亚洲综合极品香蕉久久网|