污水處理設(shè)備 污泥處理設(shè)備 水處理過濾器 軟化水設(shè)備/除鹽設(shè)備 純凈水設(shè)備 消毒設(shè)備|加藥設(shè)備 供水/儲水/集水/排水/輔助 水處理膜 過濾器濾芯 水處理濾料 水處理劑 水處理填料 其它水處理設(shè)備
珀金埃爾默醫(yī)學(xué)診斷產(chǎn)品(上海)有限公司
參 考 價(jià) | 面議 |
產(chǎn)品型號
品 牌
廠商性質(zhì)其他
所 在 地
聯(lián)系方式:查看聯(lián)系方式
更新時(shí)間:2022-10-16 12:57:56瀏覽次數(shù):83次
聯(lián)系我時(shí),請告知來自 環(huán)保在線WGA-coated SPA beads, for capturing cell membranes in proximity-based scintillation assays.
The treatment of WGA SPA beads with positively charged polyethyleneimine (PEI) blocks potential non-specific binding sites on the SPA bead surface. There are two SPA bead types available with PEI treatment. The WGA-PEI type A SPA beads are treated with PEI prior to the coupling of WGA to the SPA bead. The WGA PEI type B SPA beads are treated with PEI after the WGA coupling stage. The WGA-PEI type A and type B SPA beads exhibit different characteristics with regard to the non-specific binding of radiolabelled ligand directly to the SPA bead. Therefore, both bead types should be evaluated when deciding which SPA bead to use and both are included in the Select-a-Bead Kit. The binding capacity of both bead types for cell membrane protein remains 10–30 μg membrane protein per milligram of SPA bead.
SPA Imaging beads are microspheres containing scintillant which emit light in the red region of the visible spectrum. As a result, these beads are ideally suited to use with a CCD imager, such as PerkinElmer's Viewlux™ CCD Imager.
Two types of core SPA Imaging bead are available - yttrium oxide (YOx) and Polystyrene (PS). A number of biological coatings also exist for each core bead type to enable receptor binding, enzyme, molecular interaction and radioimmunoassays to be investigated.
Scintillation proximity assay (SPA) is a homogeneous and versatile technology for the rapid and sensitive assay of a wide range of biological processes, including applications using enzyme and receptor targets, radioimmunoassays, and molecular interactions. When 3H, 14C, 33P, and 125I radioisotopes decay, they release β-particles (or Auger electrons, in the case of 125I). The distance these particles travel through an aqueous solution is dependent on the energy of the particle. If a radioactive molecule is held in close enough proximity to a SPA Scintillation Bead or a SPA Imaging Bead, the decay particles stimulate the scintillant within the bead to emit light, which is then detected in a PMT-based scintillation counter or on a CCD-based imager, respectively. However, if the radioactive molecule does not associate with the SPA bead, the decay particles will not have sufficient energy to reach the bead and no light will be emitted. This discrimination of binding by proximity means that no physical separation of bound and free radiochemical is required.
自動化兼容 | Yes |
---|---|
珠型或核心珠型 | Polystyrene (PS) |
涂層處理 | WGA, PEI |
檢測方法 | Radiometric |
產(chǎn)品品牌名稱 | SPA Imaging Beads |
運(yùn)輸條件 | 藍(lán)冰 |
產(chǎn)品尺寸 | 50 mg |
您感興趣的產(chǎn)品PRODUCTS YOU ARE INTERESTED IN
環(huán)保在線 設(shè)計(jì)制作,未經(jīng)允許翻錄必究 .? ? ?
請輸入賬號
請輸入密碼
請輸驗(yàn)證碼
請輸入你感興趣的產(chǎn)品
請簡單描述您的需求
請選擇省份
聯(lián)系方式
珀金埃爾默醫(yī)學(xué)診斷產(chǎn)品(上海)有限公司