激情综合啪啪6月丁香,久久久久国产精品91福利,99精品日韩欧美在线观看,91成人午夜福利在线观看国产

上海騰樺電氣設備有限公司

當前位置:上海騰樺電氣設備有限公司>>西門子功能模塊>> 西門子SM1231熱電阻模塊4RTD*16BIT

西門子SM1231熱電阻模塊4RTD*16BIT

參  考  價:面議
具體成交價以合同協(xié)議為準

產(chǎn)品型號

品牌

廠商性質(zhì)經(jīng)銷商

所在地上海市

更新時間:2018-03-31 18:58:26瀏覽次數(shù):327次

聯(lián)系我時,請告知來自 環(huán)保在線
西門子SM1231熱電阻模塊4RTD*16BIT
In-line design
Type-tested according to IEC EN 60947-3
Voltage levels to 690 V AC and 440 V DC
160 A to 630 A for LV HRC fuse links and BS-88 fuse links, according to IEC 6026

西門子SM1231熱電阻模塊4RTD*16BIT 西門子SM1231熱電阻模塊4RTD*16BIT 

概述

All key product features at a glance

  • In-line design
  • Type-tested according to IEC EN 60947-3
  • Voltage levels to 690 V AC and 440 V DC
  • 160 A to 630 A for LV HRC fuse links and BS-88 fuse links, according to IEC 60269-1/EN 60269-1
  • 2-/3-/4-pole versions available
  • 185 mm center-to-center spacing of plug-in contacts
  • Manually operated or with motorized operating mechanism
  • Electronic fuse monitoring device (EFM)
  • Developed for power distribution boards in plug-in design
  • Horizontal or vertical mounting position
  • Front panel locked in ON position
  • Degree of protection IP41

Overview of all components and accessory parts

優(yōu)勢

Decisive advantages for control cabinet builders include the following:

  • Compact, modular design
  • Simple and efficient mounting due to incoming plug-in contact
  • High packing density in the field
  • Cable connection with clamps or lugs
  • Can be mounted at different control cabinet depths
  • Comprehensive range of accessories

The benefits for users are:

  • Conversion, retrofitting, and replacement without switching off the power distribution board
  • Off-circuit fuse replacement
  • Maintenance-free
  • High level of personal safety
  • Operating handle can be locked in OFF position
  • Clear and unambiguous switch position indicator

應用

The plug-in 3NJ6 switch disconnectors with fuses are installed in low-voltage distribution boards where a minimum amount of space is available for a maximum number of cable ducts to the power distribution. They can be easily fitted in all common control cabinets (minimum depth: 400 mm).

The plug-in 3NJ62 switch disconnectors with fuses are available for rated uninterrupted currents of 160 A to 630 A.

LV HRC fuse links according to IEC 60269-1 / EN 60269-1 (sizes NH 00 to NH 3) or BS fuse links according to BS 88 provide overload and short-circuit protection up to 690 V AC

The switch disconnectors can be retrofitted at any time with auxiliary switches, an ammeter (48 mm x 48 mm), and current transformers, with no extra space required. For installation in control cabinets with a depth > 400 mm, the mounting depth of the disconnectors can be increased by 200 mm using a contact extension. Further installation accessories, such as guide rails and blanking covers, complete the product range.

西門子CPU1211C主機模塊DC/DC/Rly

西門子CPU1211C主機模塊DC/DC/Rly$r$n結(jié)合使用一個

西門子CPU1212C主機模塊AC/DC/Rly

西門子CPU1212C主機模塊AC/DC/Rly$r$n通過 SIMA

西門子PLC模塊8輸入/6輸出

西門子PLC模塊8輸入/6輸出$r$nOS 標準軟件已針對提供的 SI

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復您~

以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準確性和合法性由相關企業(yè)負責,環(huán)保在線對此不承擔任何保證責任。

溫馨提示:為規(guī)避購買風險,建議您在購買產(chǎn)品前務必確認供應商資質(zhì)及產(chǎn)品質(zhì)量。

在線留言