中埋式止水帶接口的連接方法如下:
通常采用冷粘法也有熱熔連接方式。不論是哪一種,對(duì)于止水帶的施工環(huán)境要求都是:施工現(xiàn)場(chǎng)應(yīng)清潔干凈?,F(xiàn)在我們以冷粘法進(jìn)行說(shuō)明:用卡具將兩條止水帶割出兩個(gè)相反的45°角坡口,用磨毛機(jī)將止水帶背面和同材質(zhì)膠板磨毛(膠板長(zhǎng)度不小于400mm,寬度與止水帶寬度相等,各磨出250mm毛面)。另準(zhǔn)備好封口膠片,規(guī)格為厚1mm,寬150~200mm ,長(zhǎng)度比止水膠帶斷面長(zhǎng)100mm,并將粘貼面磨毛。連接前先用高標(biāo)號(hào)汽油將止水帶、膠板粘結(jié)面清洗干凈。用氯丁膠粘劑刷2~3 遍,每次干燥時(shí)間約為10min(以手觸膠粘劑稍有黏性為宜)。先將一側(cè)止水帶粘于膠板之上,再將另一側(cè)止水帶與粘于膠板上的止水帶對(duì)齊至45°角粘于膠板之上。然后用木塊沿止水帶凹槽用木錘擊打,使其粘牢。凸出部位用手輥壓,使其粘緊。對(duì)接口不嚴(yán)處,用密封膠膩?zhàn)犹顚?shí),然后在膠片與止水帶接口處刷氯丁膠粘劑,將接口包實(shí)。
Hengshui yi feng technology co., LTD., specializing in the production of rubber water-stop, buried in the rubber water-stop waterproof effect is good, quality assurance, the back rubber water-stop updated size accurate, low-cost direct manufacturer rubber water-stop steel edge, ephone: , (the same number)
中埋式止水帶的施工應(yīng)符合下列規(guī)定:
應(yīng)在其兩側(cè)混凝土齡期達(dá)到42d 后再施工,但高層建筑的橡膠止水帶應(yīng)在結(jié)構(gòu)頂板澆筑混凝土14d 后進(jìn)行;橡膠止水帶的接縫處理應(yīng)符合本規(guī)范4.1.22條的規(guī)定;混凝土施工前,止水帶安裝部位和外貼式橡膠止水帶應(yīng)予以保護(hù),嚴(yán)防落入雜物和損傷外貼式止水帶;采用補(bǔ)償收縮混凝土澆筑其強(qiáng)度等級(jí)不應(yīng)低于兩側(cè)混凝土;帶混凝土的養(yǎng)護(hù)時(shí)間不得少于28d。