LactoScope 300 tests raw and processed milk, cream and whey for fat, protein, lactose, solids and solids non-fat. It screens raw milk for abnormal content and can detect adulterants such as urea, ammonium sulphate, maltodextrin, sucrose and water.
Quick Analysis and Results
The LactoScope 300 analyses and delivers results in under 45 seconds. This allows you to run at least 80 samples in an hour.
Accurate and Reliable
Our patented Dynascan™ interferometer is designed to withstand the effects of tilts and shifts and ensures that the instrument calibration remains intact. This means that the LactoScope 300 delivers unparalleled data accuracy every time.
Intuitive Powerful User Interface
ResultsPlus™ user interface requires minimal training to go through the entire analysis and results process. This interface is also a powerful tool for administrators with higher access levels to the system as it allows them to validate calibrations and set up automatic data export to LIMS.
Remote Access and Reporting
Included with the instrument, NetPlus Report is cloud based and enables connectivity that allows you to access results from anywhere. Purchased separately, NetPlus Remote is used to configure instruments by sending calibrations and settings remotely, monitor performance by comparing instrument results to reference results and updating calibrations. For example, a processor with 10 sites can access LactoScope 300 at all sites from a single computer. They can configure them all at the same time, the same way without the need to be physically present at each site.
Specifications Lactoscope 300
Technology | FT-IR | |||||||
---|---|---|---|---|---|---|---|---|
Wavelength range | 400 – 4000 cm-1 | |||||||
Products | Raw and homogenized milk, cream, whey | |||||||
Included Calibrations | ||||||||
Milk | Parameter | Fat | Protein | Lactose | Solids | SNF | Urea | FPD |
Range | 0-13 % | 0-6 % | 0-6 % | 0-25 % | 0-12 % | 10- 30 mg/100g | 0.409 °C – 0.550 °C | |
Cream | Parameter | Fat | Protein | Lactose | Solids | SNF | ||
Range (%) | 0-45 | 0-5 | 0-5 | 0-50 | 0-12 | |||
Whey | Parameter | Fat | Protein | Lactose | Solids | |||
Range (%) | 0-10 | 2-5 | 0-5 | 0-7.5 | ||||
Accuracy | ≤ 1.2 % CV on major raw bulk tank cow milk components (Fat, Protein, Lactose, Total Solids, Solids non fat) | |||||||
Repeatability | ≤ 0.5 % CV on major raw bulk tank cow milk components (Fat, Protein, Lactose, Total Solids, Solids non fat) | |||||||
Targeted Adulterants Limits of Detection (LOD) | Urea: <> Ammonium Sulphate: <> Maltodextrin: <> Sucrose: <> Water: <> | |||||||
Untargeted Adulterant Detection | Reported as “abnormal milk” | |||||||
Sample Capture Time | < 45=""> | |||||||
Sample Temperature | 5 - 40°C | |||||||
Sample Treatment | Homogenous samples by inversion. Best performance on raw milk and cream achieved with pre-heating to 38-40 °C | |||||||
Sample Volume | 5-10 ml (milk) | |||||||
Ambient temperature | 5 - 35°C | |||||||
Humidity | Non-condensing | |||||||
Data Interface | 2 x USB Ports (for printer, keyboard, mouse or barcode reader) 1 x Ethernet port | |||||||
Operating System | Windows™ | |||||||
Remote Connection | NetPlus™ | |||||||
Display | 12” color touchscreen | |||||||
Carry Over | <> | |||||||
Cleaning | Automatic and programmable | |||||||
Power Supply | 100/230 V, 50/60 Hz, 12 V operation | |||||||
Dimensions (W x D x H) | 460 x 440 x 600 mm | |||||||
Weight | 22 kg | |||||||
Dust / Water classification | IP22 for main cabinet, hermetically sealed FTIR optics |
規(guī)格
便攜式 | No |
---|---|
產(chǎn)品品牌名稱 | PerkinElmer |
技術(shù)類型 | FT-IR |